Description: Spot - Service degradation across multiple cloud providers
Timeframe: November 3, 2026, 2:17 AM PDT - November 3, 2026, 3:08 AM PDT
Incident Summary
On Tuesday, November 3, 2026, at 2:17 AM PDT , a subset of customers using Flexera One Spot experienced a temporary service disruption affecting background monitoring and scheduled scaling operations for Elastigroup and Ocean workloads across cloud providers. Core platform availability remained accessible throughout the event; however, some automated scheduled tasks, including scheduled scale-up and scale-down actions, were delayed or affected during the disruption window.
Technical teams began investigating following automated monitoring alerts that detected elevated HTTP 5xx error rates and reduced background task throughput across supporting monitoring services. The investigation determined that a routine credential rotation updated the deployment configuration of a core monitoring service, triggering a progressive rolling replacement of its underlying compute instances. While partial service capacity remained available throughout the rollout, the temporary reduction in processing capacity resulted in elevated error responses and delayed execution of scheduled background operations.
As the progressive rollout completed, replacement instances initialized and passed health checks, restoring full service capacity automatically without requiring manual intervention. Monitoring alerts recovered and normal background task processing resumed by 3:08 AM PDT. Post-recovery validation confirmed that scheduled scaling operations and monitoring routines were functioning normally across all supported cloud providers, with no residual impact identified.
Root Cause
The incident was caused by a routine security credential rotation for a core Spot monitoring service. The rotation changed the service configuration and triggered a progressive replacement of its active service instances.
During the replacement process, service capacity remained available, but the number of active processing instances was temporarily reduced. The remaining capacity was insufficient to process all concurrent background activity at normal levels, resulting in elevated error responses and causing some scheduled background operations, including automated scaling tasks, to be dropped or delayed.
Service capacity recovered as the replacement process completed and the full set of service instances stabilized, allowing normal background processing to resume.
Contributing Factors
Remediation Actions
The following actions were taken during the incident response:
Future Preventative Measures
Following the incident, the following preventative measures have been initiated: